Mining cable sheathing compou..
          Common rubber jacketed flexib..
          Household electrical applianc..
          Marine cable sheathing compou..
          Wind power cable CPE sheathin..
          Welder cable sheathing compou..
          EPDM insulation compound..
          Semi-conductive shielding com..
          Compound for wire reinforced ..
          More
 
  Products

EPDM insulation compound

This products implements performance requirements for EPDM insulated rubber of national standard GB/T 7594-87 and is suitable for insulating layers of common rubber sheathed cable, mining cable, UCPJB, UCPJR, wind power cable, and etc. Its mechanical, physical and electrical properties are as follows:
Indicator requirements and measured performance

Test item Unit HJ-1 HJ-2 HJ-3
Standard requirements Typical values Standard requirements Standard requirements Typical values Standard requirements
Initial tensile strength Mpa ≥5.0 6.5 ≥5.0 7.5 ≥4.2 8.0
Elongation at break % ≥250 280 ≥250 290 ≥200 240
Thermal aging of air box Conditions 75±2℃×240h 80±2℃×240h 135±2℃×168h
Tensile strength change rate % ±30 +8 ±30 +9.0 ±30 +10.0
Change rate of elongation at break % ±30 -8 ±30 -10.0 ±30 -15.7
Thermal extension test Conditions 200±2℃× 15 min×0.2MPa 250±3℃× 15 min×0.2MPa min×0.2MPa min×0.2MPa
Elongation under load % ≤175 75 ≤175 68 ≤175 68
Permanent deformation after cooling % ≤25 18 ≤20 15 ≤15 11
Volume resistivity at 20℃ Ω﹒m ≥1.0×1013 5.5×1013 ≥1.0×1014 7.2×1014 ≥1.0×1015 6.7×1015
Dielectric strength MV/m   26   28   28
Ozone resistance Conditions 250±2℃× 24h ×0.025~0.03%
Results         No cracks No cracks

Copyright(C)2017 , Shandong Hongjian Polymer Material Technology Co., Ltd. All Rights Reserved.  Supported by  ChemNet  ChinaChemNet Toocle Copyright Notice